Standard+ V2 (10231-2)

DCCWiki, a community DCC encyclopedia.
Jump to: navigation, search

Multifunction Decoder:

Lenz: Standard+ V2 (10231-2)

Summary: Lenz Standard+ V2 HO decoder with 4 functions. Suitable for all DC locomotives with a continuous current draw of 1.0 Amp. or less.

See more Multifunction Decoders
General information
Manufacturer Lenz
CV7 ID# 77
MSRP
Compare Prices Latest Prices
Product information
Manufacturer
Part Number
10231-2

Common Name Standard+ V2
Decoder Core Features Functions, Lights

Product Manual URL External Product Link
Predecessor 10231-1
Successor
Hardware Information
Scales HO
Connection Method 8 Pin / NEM652
Length 2525 cm <br />250 mm <br />0.25 m <br />9.843 in <br />0.82 ft <br />
Width 1515 cm <br />150 mm <br />0.15 m <br />5.906 in <br />0.492 ft <br />
Height 3.83.8 cm <br />38 mm <br />0.038 m <br />1.496 in <br />0.125 ft <br />
Continuous Amps 1
Max Amps 1
Voltage Range
General DCC Information
Extended Addressing Yes
AnalogConversion Yes
Speed Steps 14, 28/128
User Loadable Speed Table Yes
Back EMF Yes
Programming Modes Ops, Address, Direct, Paged, Register
Decoder Assisted Consists Yes
CV Readback
Silent Running (HF) Yes
Dither
Kick Start
Momentum Yes
Function Information
# of Functions 4
Function Amps 150mA
# of Lighting Effects 10
# of Sound Effects 0
Programming Information
Programming Lock Yes
Decoder Programming Modes
Misc Items
SUSI Interface
RailCom
USP
Transponding
Has computer interface
Firmware Upgrade Possible No
UPC Number

History

Decoder manual is dated 11/20.

Standard Silent-Back EMF DCC Decoder

Features

  • Super smooth and silent high frequency Back EMF motor control.
  • Adjustable precision stopping control
  • Low speed gear for switching operations
  • Selectable for operation with 14/27, or 28/128 speed steps.
  • Operation on conventional DC layouts is possible or can be disabled.
  • Motor output = 1A continuous.
  • Motor and function outputs protected
  • Four function outputs rated at 150mA each when using light bulbs. This has advanced function mapping. Total output of functions should not exceed 750mA.
  • Directional or independent lighting with dimming and special effects.
  • Support for Advanced Consist Control and Extended Addressing
  • Support for programming on the mainline (operations mode programming)
  • Support for all form of programming as described in NMRA RP-9.2.3
  • Supports service mode decoder lock

Motor Drive Frequency is 19 or 23kHz.

Decoder Reset: Write a value of 33 in CV8. Software revision is found in CV128.