This is based on adjusting the output voltage for an LZV200.
Setting the Track Voltage
The voltage range of the LZV200 can be adjusted from 11 to 22 volts. The factory setting is 16V.
Process
This process will use Operations Mode Programming, with a handheld throttle.
- Change to program mode
- Select any valid locomotive address in Operations Mode
- Select CV7
- Enter a value of 50. This puts the LZV into program mode
- This mode will time out in fifteen seconds
- Enter a value from the table below to set the voltage
Voltage Output Adjustment, Lenz | |
---|---|
UA (Volts) | CV7 |
11 | 22 |
11.5 | 23 |
12 | 24 |
12.5 | 25 |
13 | 26 |
13.5 | 27 |
14 | 28 |
14.5 | 29 |
15 | 30 |
15.5 | 31 |
16 | 32 |
16.5 | 33 |
17 | 34 |
17.5 | 35 |
18 | 36 |
18.5 | 37 |
19 | 38 |
19.5 | 39 |
20 | 40 |
20.5 | 41 |
21 | 42 |
21.5 | 43 |
22 | 44 |